We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

The purpose of this study was to investigate the robustness of different radiography radiomic features over different radiologic parameters including kV, mAs, filtration, tube angles, and source skin distance (SSD). A tibia bone phantom was prepared and all imaging studies was conducted on this phantom. Different radiologic parameters including kV, mAs, filtration, tube angles, and SSD were studied. A region of interest was drawn on the images and many features from different feature sets including histogram, gradient, run-length matrix, co-occurrence matrix, autoregressive model, and wavelet derived parameters were extracted. All radiomic features were categorized based on coefficient of variation (COV). Bland-Altman analysis also was used to evaluate the mean, standard deviation, and upper/lower reproducibility limits for radiomic features in response to variation in each testing parameters. Results on COV in all features showed that 22%, 34%, and 45% of features were most robust (COV ≤ 5%) against kV, mAs, and SSD respectively and there was no robust features against filtration and tube angle. Also, all features (100%) and 76% of which showed large variations (COV > 20%) against filtrations and tube angle respectively. Autoregressive model feature set has no robust features against all radiologic parameters. Features including sum-average, sum-entropy, correlation, mean, and percentile (50, 90, and 99) belong to co-occurrence matrix and histogram feature sets were found as most robust features. Bland-Altman analysis showed the high reproducibity of some feature sets against radiologic parameter changes. The results presented here indicated that radiologic parameters have great impacts on radiomic feature values and caution should be taken into account when work with these features. In quantitative bone studies, robust features with low COV can be selected for clinical or research applications. Reproducible features also can be obtained using Bland-Altman analysis.

Original publication

DOI

10.1016/j.jocd.2018.06.004

Type

Journal article

Journal

Journal of Clinical Densitometry

Publication Date

01/04/2019

Volume

22

Pages

203 - 213