We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

AIMS: To prospectively evaluate homograft function with cardiac magnetic resonance (CMR) imaging 1 year after insertion into the pulmonary position, and to assess the impact of in situ homograft geometry, surgical factors, and 'intrinsic' homograft properties on early valve incompetence. METHODS AND RESULTS: A total of 60 patients (mean age 21 +/- 10 years; 35 females) with congenital heart disease underwent pulmonary valve replacement with homograft insertion and were prospectively enrolled into a study protocol that included serial echocardiography and CMR 1 year after surgery. None of the patients had homograft stenosis but 10 (17%) had significant homograft incompetence (i.e. pulmonary regurgitation fraction >20% on CMR). A higher incidence of 'eccentric' pulmonary forward flow pattern (P < 0.001, Fisher's exact test), more acute 'homograft distortion angle' (P < 0.001), larger relative 'annular' size (P < 0.01), and greater pre-homograft right ventricular outflow tract (RVOT) diameters (P = 0.01) at CMR was seen in those with worse homograft function. In a backward multivariate linear regression model, 'eccentric' pulmonary forward flow pattern (r(part) = 0.36, P < 0.001), 'homograft distortion angle' (r(part) = 0.31, P = 0.001), and pre-homograft RVOT diameter (r(part) = 0.19, P = 0.03) were independently associated with the degree of pulmonary regurgitation (in %) at 1 year. CONCLUSION: Using CMR, in this prospective cohort study, we have shown that significant valve incompetence is present in one-sixth of patients after homograft insertion into the pulmonary position, and that alterations in the in situ homograft geometry were associated with the likelihood of developing valve incompetence. These findings imply that mechanical factors may have an important impact on homograft performance.

More information Original publication

DOI

10.1093/eurheartj/ehp204

Type

Journal article

Publication Date

2009-09-01T00:00:00+00:00

Volume

30

Pages

2147 - 2154

Total pages

7

Keywords

Adult, Echocardiography, Female, Graft Survival, Heart Defects, Congenital, Heart Valve Prosthesis, Heart Valve Prosthesis Implantation, Humans, Magnetic Resonance Angiography, Male, Prospective Studies, Pulmonary Valve, Pulmonary Valve Insufficiency, Stroke Volume, Transplantation, Homologous, Treatment Outcome, Young Adult